Roth Technologies, LLCIndustrial seals for moving wire processes
Replacement and retrofit guidance

Replacement for baby nipples on wire-coating lines?

If an existing wire-coating line uses a baby-nipple-style seal at a bath entry, a Moving Wire Seal may be worth evaluating. Treat it as an application review, not an assumed drop-in replacement.

Compare the job the seal performs

Compare the job the seal performs

First confirm whether the existing part seals the bath entry, guides the wire, wipes coating, or performs more than one function. MWS products are designed to seal a moving-wire path into an applicator bath or treatment tube; they do not meter coating thickness.

Check geometry before ordering

Check geometry before ordering

Compare the holder opening, wall thickness, seal outside dimensions, wire center spacing, wire count, and wire diameter. MWS-004 is the standard 1.0-inch-center configuration listed in black EPDM, 35A. JRS supports a closer 0.5-inch center layout; the flat NPL options address other small-wire layouts. Confirm current drawings and availability.

Review material and operating conditions

Review material and operating conditions

A replacement must suit the actual liquid or chemical, temperature, line speed, pressure conditions, and cleaning method. The MWS is supplied without a tip opening; the end user creates an opening for the wire and application. Validate the retrofit on the intended line before relying on it in production.

Starting tip-opening fit: Use the wire outside diameter at the seal, including any coating already on it, as a nominal 1:1 starting size. The MWS application guidance calls for light wipe contact, not a loose clearance or a pinching fit. No universal oversize percentage is specified; confirm by trial with the actual wire and line conditions.
Application note: MWS is a configurable alternative to evaluate, not a guaranteed dimensional or functional drop-in replacement.