Roth Technologies, LLCIndustrial seals for moving wire processes
PTFE dispersion bath integration

PTFE dispersion bath bottom seal for moving wire

A Moving Wire Seal (MWS) can close the wire entry at the floor of a non-pressurized applicator bath while allowing a continuously moving wire to pass into the dispersion.

The seal belongs at the wire entry

The seal belongs at the wire entry

In a vertical coating arrangement, the MWS is installed in the bath floor or holder. The wire passes through a small opening made by the end user in the supplied closed tip. The MWS helps seal the entry boundary; it does not set bath level, meter wet-film thickness, or replace a coating die.

Choose the configuration around the line

Choose the configuration around the line

MWS-004 is the standard configuration listed in black EPDM, 35A, for the standard 1.0-inch center layout. Wire count and spacing, tip opening, holder geometry, temperature, pressure conditions, and exposure all affect selection. Confirm the drawing and installation dimensions before fabrication.

Qualify the wetted material

Qualify the wetted material

PTFE dispersion formulations and process conditions vary. Confirm compatibility for the actual liquid, temperature, cleaning method, and exposure duration. The simulator estimates coating build under stated assumptions; it does not establish seal compatibility or seal performance.

Starting tip-opening fit: Use the wire outside diameter at the seal, including any coating already on it, as a nominal 1:1 starting size. The MWS application guidance calls for light wipe contact, not a loose clearance or a pinching fit. No universal oversize percentage is specified; confirm by trial with the actual wire and line conditions.
Application note: Use the MWS as a bath-entry seal, not as a coating-thickness control.
Need to size the MWS opening? Use Hole Sizing to explore independent fit choices and estimated contact loads at each pass. Open the Hole Sizing calculator.